CONVEYVAC TECHNICAL DATA

ConveyVacs > Solutions > Technical Data

ConveyVac / StrongMan ConveyVac Dimensions

ConveyVac / StrongMan ConveyVac Dimensions

ConveyVac Dimensions
Aluminum
Stainless
A
Inch / mm

B
C
D
E
F
Air Consumption
@ 80 psi
98004
90004
0.75"
19
2.8
1/8" NPT
3.75"
.50"
.42"
28 cfm
98008
90008
1"
25
3.5"
1/4 NPT
0.80"
1"
1.50"
28 cfm
98012
90012
1.5"
38
5.7"
1/4 NPT
1.25"
1.5"
2.75"
28 cfm
98022
90022
3"
75
6"
3/8 NPT
2.25"
1.5"
4.00"
32 cfm
98032
90032
4"
101
8"
1/2 NPT
3.25"
2"
5.00"
42 cfm
98042
90042
6"
150
10"
1/2 NPT
4.25"
2"
6.00"
52 cfm

StrongMan ConveyVac Dimensions
Aluminum
Stainless
Threaded
Stainlness

A
Inch / mm

B
C
D
E
F
Air Consumption@ 80 psi
98104
98204

0.75"
19
2.8"
1/8" NPT
3.75"
.50"
.42"
25 cfm
98108
98208
90308
1"
25
3.5"
1/4 NPT
0.80"
1"
1.50"
56 cfm
98112
98212
90312
1.5"
38
5.7"
1/4 NPT
1.25"
1.5"
2.75"
60 cfm
98122
98222

3"
75
6"
3/8 NPT
2.25"
1.5"
4.00"
92 cfm
98132
98232

4"
101
8"
1/2 NPT
3.25"
2"
5.00"
110 cfm
98142
98242
90342
6"
150
10"
1/2 NPT
4.25"
2"
6.00"
118 cfm

Compressed Air Supply

Air supplies are plagued with condensed water vapor in the air lines. This condensation leads to rust and dirt in the air lines. Also some compressors will allow oil or oil vapor to enter the line. Small orifices in the AIRTX Air Saver products may become clogged with the rust dirt, and water droplets. A 5-micron filter will separate 99% of the foreign material from the air supply allowing virtually maintenance free operation. The use of an oil filter will remove the oil droplets with an effective filtration of 0.01 ppm for an even cleaner air supply. Keep in mind that the current line or air might contain dirt or oil and should be blown out before installation. Also pipe thread sealant or tape must be carefully applied to avoid clogging product orifices.

Airtx Product Performance/Compressed Air Supply Line Size

To obtain maximum performance from the AIRTX ConveyVac, accurate measurements of air pressure (psi) and air volume (cfm) must be obtained. Line pressure of 70-90 psi can be present without sufficient volume (cfm) of air. To ensure that both pressure and volume are present to efficiently operate the AiRTX products, a line size of 1/4“ pipe or 1/2” hose should be used for applications up to 10ft. from the main header. Use 3/8” pipe or 3/4” hose up to 20 ft. and 3/4” pipe and 1” hose up to 50 feet. Do not use coiled hose as the very small inside diameter of the hose limits air flow. Avoid 90° bends in the air hose leading to the vacuum side or exit side of the ConveyVac as this creates turbulence in the flow and limits the effectiveness.

 