NOZZLES: MORE PERFORMANCE, LESS NOISE
Air Saver Nozzles give you more performance with less noise.
Lowering the sound level by 30%
Noise level of AiRTX Air Amplifiers and Nozzles
|
Model |
Noise level dBA
|
psi
|
cfm
|
38038
|
76
|
@80
|
15
|
48009
|
72
|
@80
|
15
|
15008
|
72
|
@80
|
15
|
15015
|
76
|
@80
|
20
|
85006
|
72
|
@80
|
24
|
85012
|
72
|
@80
|
48
|
38050
|
74
|
@80
|
15
|
General Information on Noise in the Workplace
Sound Level
|
Application
|
Recommended NIOSH Tolerance (w/o ear protection)
|
110 |
1/2" Open Pipe
|
30 min.
|
105
|
3/8" Open Pipe
|
1 hr.
|
102
|
1/4" Copper Tube
|
90 min.
|
92
|
|
6 hrs.
|
90
|
|
8 hrs.
|
85
|
Targeted sound levels for most manufacturing facilities
|
60
|
Normal conversation — An increase or decrease of 10% in sound levels makes a substantial difference in the ear damaging effects of noise
|
|
|